Site Overlay

IECEx Certified Installer & Inspector (Ex001, Ex003, Ex007 and Ex008)

IECEx Certified Installer & Inspector

Ex001, Ex003, Ex007 and Ex008

IECEx Training & Certification Program suitable to workers on installing, maintaining, testing, repairer and auditing electrical/ instrument installation located in potentially explosive atmosphere. This course covers the explosion-protection aspects for installing explosion protected and associated equipment and wiring systems. It requires the ability to match equipment with that specified for a given location, work safely, and to installation Standards and complete the necessary installation documentation.

Evaluating the completeness of a hazardous area verification dossier and compliance of the explosion protected aspects of the electrical installations within the constraints of a visual or close inspection. It requires the ability to work safely in a hazardous area, evaluate a verification dossier, identify explosion-protected equipment with their certification and specified location, inspect an installation for compliance and report and act on inspection results. This course is based on IEC 60079-14 and any other relevant standard that apply to the Unit of Competency. For installation all types of protection shall be understood.

Objectives
  • Understand about IECEx scheme and service being offered
  • Understand what had happened in this industry
  • Understand the requirement needs
  • Able to identify the type of doing hazardous area classification
  • Able to read and make the comparison of the equipment and hazardous area specification
  • Able to classify Ex methodology, design characteristic, zoning, installation, maintenance, inspection criteria for Ex
Course Contents
  • Trainer info, trainer experience share and participants experience sharing
  • IECEx Intro, Scheme and Overview
  • Ex History and past accidents
  • Ex requirement, and PTS
  • Combustible Gas
  • Combustible Dust
  • Safe work procedure in Hazardous Area
  • Hazardous Area classification
  • Ex Marking
  • Protection Technique
    • Ex d – Flameproof
    • Ex e – Increased Safety
    • Ex n – Non Sparking
    • Ex I – Intrinsically Safe
    • Ex p – Pressurization
    • Others – Ex o, Ex m, Ex q, Ex s and Ex v
  • Knowledge on Selection and Installation in Hazardous Area (IECEx Ex003)
  • Practical Session 01 – Installation In Hazardous Area
  • Visual and Close Ex Inspection – Theory and doing Ex inspection in Hazardous Area – Unit Ex007
  • Detailed Inspection in Hazardous Area for E&I equipments – Unit Ex008
Training Method
  • Theory Class
  • Practical
  • Case Studies & Discussion
  • Quiz/Assessment
Duration

5 days training and 2-day examination (will arrange to our examination partner after completing the training session)

Who Should Attend
  • Manager
  • Engineer
  • Supervisor
  • Inspector
  • Technician
  • QA/QC Personnel
  • Installation & Maintenance Personnel
  • HSE Officers
Course Schedule

Time: 9.00 AM until 5.00 PM

Date Available:

  • 19 – 23 February 2024
  • 22 – 26 April 2024 (Shah Alam)
  • 13 – 17 May 2024 (Bintulu)
  • 24 – 28 June 2024 (Bintulu)
  • 12 – 16 August 2024
  • 18 – 22 November 2024

×
;