IECEx Certified Installer & Inspector
Ex001, Ex003, Ex007 and Ex008
IECEx Training & Certification Program suitable to workers on installing, maintaining, testing, repairer and auditing electrical/ instrument installation located in potentially explosive atmosphere. This course covers the explosion-protection aspects for installing explosion protected and associated equipment and wiring systems. It requires the ability to match equipment with that specified for a given location, work safely, and to installation Standards and complete the necessary installation documentation.
Evaluating the completeness of a hazardous area verification dossier and compliance of the explosion protected aspects of the electrical installations within the constraints of a visual or close inspection. It requires the ability to work safely in a hazardous area, evaluate a verification dossier, identify explosion-protected equipment with their certification and specified location, inspect an installation for compliance and report and act on inspection results. This course is based on IEC 60079-14 and any other relevant standard that apply to the Unit of Competency. For installation all types of protection shall be understood.
Objectives
- Understand about IECEx scheme and service being offered
- Understand what had happened in this industry
- Understand the requirement needs
- Able to identify the type of doing hazardous area classification
- Able to read and make the comparison of the equipment and hazardous area specification
- Able to classify Ex methodology, design characteristic, zoning, installation, maintenance, inspection criteria for Ex
Course Contents
- Trainer info, trainer experience share and participants experience sharing
- IECEx Intro, Scheme and Overview
- Ex History and past accidents
- Ex requirement, and PTS
- Combustible Gas
- Combustible Dust
- Safe work procedure in Hazardous Area
- Hazardous Area classification
- Ex Marking
- Protection Technique
- Ex d – Flameproof
- Ex e – Increased Safety
- Ex n – Non Sparking
- Ex I – Intrinsically Safe
- Ex p – Pressurization
- Others – Ex o, Ex m, Ex q, Ex s and Ex v
- Knowledge on Selection and Installation in Hazardous Area (IECEx Ex003)
- Practical Session 01 – Installation In Hazardous Area
- Visual and Close Ex Inspection – Theory and doing Ex inspection in Hazardous Area – Unit Ex007
- Detailed Inspection in Hazardous Area for E&I equipments – Unit Ex008
Training Method
- Theory Class
- Practical
- Case Studies & Discussion
- Quiz/Assessment
Duration
5 days training and 2-day examination (will arrange to our examination partner after completing the training session)
Who Should Attend
- Manager
- Engineer
- Supervisor
- Inspector
- Technician
- QA/QC Personnel
- Installation & Maintenance Personnel
- HSE Officers
Course Schedule
Time: 9.00 AM until 5.00 PM
Date Available:
- 19 – 23 February 2024
- 22 – 26 April 2024 (Shah Alam)
- 13 – 17 May 2024 (Bintulu)
- 24 – 28 June 2024 (Bintulu)
- 12 – 16 August 2024
- 18 – 22 November 2024